GW1118-8DI(RS-485)-TB-P(12-48VDC)

8 Port RS-485 to Ethernet Modbus Gateway

Support 8 RS-485 serial ports to 2 10/100Base-T(X) self-adaptive Ethernet interfaces
Support conversion between Modbus RTU/ASCII and Modbus TCP protocol
Support RTU Master, RTU Slave, ASCII Master, ASCII Slave and other operating modes
Support virtual and real ID mapping to achieve flexible access between Master and Slave devices
Support network modes such as redundant mode, switching mode and dual IP mode to meet the needs of various network environments
Support 12~48VDC wide voltage input range
Support -40~75℃ wide operating temperature range

GET A QUOTE
Overview
Specifications
Models
Resources

Overview of 3onedata's 8 Port RS-485 to Ethernet Modbus Gateway GW1118-8DI(RS-485)-TB-P(12-48VDC)

GW1118-8DI(RS-485)-TB-P(12-48VDC) is Modbus gateway designed for integrating Modbus RTU/ASCII and Modbus TCP networks; it can achieve the conversion between Modbus RTU/ASCII and Modbus TCP protocols. This product supports 8 RS-485 serial ports to 2 10/100Base-T(X) self-adaptive Ethernet port. It adopts desktop/wall mounting to meet the requirements of different application scenes.
Modbus gateway supports multiple network protocols, such as Modbus, TCP, IP, UDP, TELNET, ARP, ICMP, HTTP, HTTPS, SNMP, SSH,SMTP, SNTP,DNS and DHCP protocols. It possesses complete management function, and supports access control, rapid configuration, online upgrading, etc. RTU Master, RTU Slave, ASCII Master, ASCII Slave and other operating modes are supported; it supports up to 256 Modbus TCP client (master) accesses and connects up to 128 Modbus TCP server (slave) devices. TELNET, WEB, SSHD and other access modes are also supported. It can provide users with good experience with friendly design of network management system interface, simple and convenient operation.
RESET button can achieve the restore factory defaults function. Each RS-485 serial port of the device is equipped with an exclusive isolation component, which can effectively avoid the impact of electromagnetic interference.  Hardware adopts fanless, low power consumption, wide temperature and voltage design and has passed rigorous industrial standard tests, which can suit for the industrial scene environment with harsh requirements for EMC. It can be widely used in PLC control and management, Building Automation System, Health Care Automation System, measuring instrument and environmental forces monitoring system.


Additional Features
Support 2 10/100Base-T(X) self-adaptive Ethernet interfaces and provide dual IP and MAC addresses to meet the requirements of multi-network management or network backup.
Support 110bps-115200bps (customizable 921600bps) line speed and non-blocking communication
Support RTS/CTS, DTR/DSR and XON/XOFF flow control
Support response timeout setting of characters
Support RTU Master, RTU Slave, ASCII Master, ASCII Slave and other operating modes
Support up to 256 Modbus TCP client (master) accesses and connect up to 128 Modbus TCP server (slave) devices
Support virtual and real ID mapping to achieve flexible access between Master and Slave devices
Support IP address and MAC address filtering, which can achieve accurate access control easily
Support graded user management to implement humanized authority management
Support serial port status and parameters monitoring, ensuring the communication status is easy to read
Support multiple configuration forms and access controls like Windows configuration tool, TELNET, SSHD and WEB
File management is convenient for the device rapid configuration and online upgrading
SSHD and HTTPS can guarantee the access security of data
Conduct network diagnosis and troubleshooting via Ping and Traceroute